Siemens SpeedStream 4200

From TechInfoDepot
(Redirected from SpeadStream 4200)
Jump to navigationJump to search
multiple revisions of this device, use caution
Ethernet ADSL Modem
InfoDepot Wiki
WikiDevi.wi-cat.ru
3rd Party Firmware
dd-wrt
OpenWrt
Incompatible
Tomato any flavor
Incompatible
Platform
BrandModelRev
Siemens SpeedStream 4200
Type
dsl modem
CPU1
Texas Instruments TNETD7300A
CPU1 Type
MIPS 4KEc
CPU1 Speed
160 MHz
Flash1 Chip
Macronix MX29LV160
Flash1 Size
2 MiB2,097,152 B <br />16,384 Kib <br />2,048 KiB <br />16 Mib <br />0.00195 GiB <br />
RAM1 Size
16 MiB16,777,216 B <br />131,072 Kib <br />16,384 KiB <br />128 Mib <br />0.0156 GiB <br />
RAM1 Chip
Samsung K4S281632F-TC60
ETH chip1
Texas Instruments TNETD7300A
Ethernet Port Count
1-100MbE-LAN
Wired Standard
IEEE 802.3i/3u
Expansion IF types
USB 1.1
USB ports
1
USB Hub Compatible
Untested
Power
12 VDC, 0.5 A
Connector type
barrel
Flags:
ADSL2+
Other

Default IP address: 192.168.254.254
the IP 192.168.254.254 is used by 11 additional devices
of which 7 are Siemens devices
Default login user: admin
Default login password: blank
admin:blank credentials used by 365 additional devices
of which 1 are Siemens devices

Retail
(Est.) release date 01 March 2004
Country of manuf China
 CPU1 brandFLA1RAM1
Siemens SpeedStream 4100Texas Instruments2 MiB2,097,152 B <br />16,384 Kib <br />2,048 KiB <br />16 Mib <br />0.00195 GiB <br />8 MiB8,388,608 B <br />65,536 Kib <br />8,192 KiB <br />64 Mib <br />0.00781 GiB <br />
Siemens SpeedStream 4200Texas Instruments2 MiB2,097,152 B <br />16,384 Kib <br />2,048 KiB <br />16 Mib <br />0.00195 GiB <br />16 MiB16,777,216 B <br />131,072 Kib <br />16,384 KiB <br />128 Mib <br />0.0156 GiB <br />
Siemens SpeedStream 6520 (060-N651-A20)Texas Instruments16 MiB16,777,216 B <br />131,072 Kib <br />16,384 KiB <br />128 Mib <br />0.0156 GiB <br />

For a list of all currently documented Texas Instruments (TI) chipsets with specifications, see Texas Instruments.

For a list of all currently documented Siemens device with specifications, see Siemens.

Overview

Notes

Instructions on how to bridge a SpeedStream 4200 • >>

As we seem to get asked a lot for instructions on how to bridge a SpeedStream 4200, and test

if it bridged correctly i have copied info from the Siemens site to make it easy to find

plz note instructions are for use with ethernet and not usb,

i suggest you only use ethernet with the 4200

Instructions for making the necessary changes are set out below:

SpeedStream 4200 to Bridge Mode

4200 Modem set-up:

  • Reset the modem to ensure it is in default mode (refer instructions below).
  • Type the modem's URL into the internet browser (address bar in Internet Explorer)
Note: You need to determine the DHCP server address for the modem.
For Windows 2000 or XP, this can be performed by selecting “Run” from the “Start” menu:
• type cmd, then enter
• at the DOS prompt, type: ipconfig /all, then enter
• note the DHCP server address. This is the modem address.
  • Click "Login" option. The "Username" is admin and the "Password" is admin. Then click "OK".
  • Click the "Setup" option and then click the "WAN interface" option.
  • If asked for a Username/Password use admin/admin
  • Click under VC heading the "8/35" option.
  • Click "Next>>"
  • The PPPoE option should be selected and then click "Next>>" again.
  • Under the heading "PPPoE Type" select the "Bridge only" option and then click "Next>>".
  • Click "Finish"
  • A reboot is required before the new configuration takes effect. Click the word "reboot".
An additional "Reboot" button will be displayed. Click this "Reboot" button"

Resetting 4200 to Factory Defaults

Resetting the modem may be required if you have changed the modem’s settings

and wish to reset it to the factory default configuration.

Note: Resetting the modem will wipe all previous configurations and you will

need to re-enter your provider account details.

4200 Modem

  • 1. Using the tip of a ballpoint pen or unfolded paperclip, press and hold the Reset button located
on the bottom of the router. The pwr LED will blink red once, indicating that the reset has begun.
  • 2. Continue depressing the Reset button for four seconds or until the pwr LED begins to blink
alternating red-to-green.
  • 3. Release the Reset button.

Generic 4200 firmware: http://www.modemsupport.com.au/ (see left hand menu)

4200 user manual: http://www.modemsupport.com.au/


  • To test the 4200 is actually running in bridge mode

connect a computer directly to the 4200 with an ethernet cable

you will need to run a windows ppp session , you can delete the ppp session

once you have confirmed it works correctly

PC setup for running PPPoE (for Windows):

  • Go to the Control Panel from the Start Menu
  • Click Network Connections
  • Under the Wizard heading – click “New Connection Wizard”
  • At the Network Connection Type screen, click “Connect to the Internet”
  • Select “Setup my connection manually”
  • Select “ Connect using a broadband connection that requires a user name and password”
  • @ the Connection Name Screen, type in myisp where it asks for the ISP name
  • @ the Connection Availability screen select “Anyones Use”
  • @ Internet Account Information screen, enter your user name and details and ensure both
of the check boxes, are ticked ie for “use this account name and password when anyone anyone
connects to the internet from this computer”, and “make this the default internet connection”.
  • Completion of New Connection Wizard, tick “add a shortcut to this connection to my desktop”.

To go online, every time you wish to connect, double click the myisp icon, enter

your user name and password and click “connect”.

once you confirm the above works you must remove this test setup from your computer,

to do this go to start / settings / control panel

select internet options / select the connections tab --- click on "myisp" and select

remove , this resets your computer back to normal.

If the above allows you to connect directly to the net then you are in bridge mode

and ready to connect a router or wireless router to the 4200